Revere Testing Data
Serving Colorado Families Since 1990

  Carefree Exteriors
Aurora, CO 80014
Tel: 303.693.8553
Replacement Window Prices 
Site InstructionsWorksheetMeasuring Instructions PricingHome ProductsWarrantiesHome
ResourcesAbout UsContact UsComparisons and RatingsInstallationQuestions and AnswersCustomers by Zip


Revere Replacement Window Testing Data

Back to Comparisons

Amhurst® Double Hung Model 0901
Structural
AAMA 101/I.S. 2-97 DP H-LC35
Test Size 44" x 77"
Loads 60.0 PSF
Water 5.25 PSF
Air @ 25 mph 0.14 CFM/FT
Thermal-NFRC 100-97
  U-Value U-Value
Size 36" x 60" 48" x 72"
Clear .50 .50
Low-E/Argon (ClimaTech) .34 .32
Low-E/Argon SST .32 .31
 
Amhurst® Slider Model 0902
Structural
AAMA 101/I.S. 2-97 DP H-LC30
Test Size 72" x 54"
Loads 45.0 PSF
Water 5.25 PSF
Air @ 25 mph 0.13 CFM/FT
Thermal-NFRC 100-97
  U-Value U-Value
Size 36" x 60" 48" x 72"
Clear .50 .50
Low-E/Argon (ClimaTech) .34 .32
Low-E/Argon SST .32 .31

Top of Page

Berkshire® Double Hung Model 0201
Structural
AAMA 101/I.S. 2-97 DP H-LC30
Test Size 44" x 77"
Loads 45.0 PSF
Water 4.5 PSF
Air @ 25 mph 0.15 CFM/FT
Thermal-NFRC 100-97
  U-Value U-Value
Size 36" x 60" 48" x 72"
Clear .50 .50
Low-E/Argon (ClimaTech) .31 .32
Low-E/Argon SST .30 .29
 
Berkshire® Slider Model 0202
Structural
AAMA 101/I.S. 2-97 DP H-LC25
Test Size 72" x 54"
Loads 37.5 PSF
Water 5.25 PSF
Air @ 25 mph 0.10 CFM/FT
Thermal-NFRC 100-97
  U-Value U-Value
Size 36" x 60" 48" x 72"
Clear .49 .49
Low-E/Argon (ClimaTech) .30 .29
Low-E/Argon SST .30 .29

Top of Page

Sovereign® Double Hung Model 0601
Structural
AAMA 101/I.S. 2-97 DP H-LC40
Test Size 44" x 77"
Loads 60.0 PSF
Water 6.0 PSF
Air @ 25 mph 0.18 CFM/FT
Thermal-NFRC 100-97
  U-Value U-Value
Size 36" x 60" 48" x 72"
Clear .46 .47
Low-E/Argon (ClimaTech) .31 .30
Low-E/Argon SST .29 .28
 
Sovereign® Slider Model 0602
Structural
AAMA 101/I.S. 2-97 DP H-LC45
Test Size 72" x 54"
Loads 67.5 PSF
Water 6.75 PSF
Air @ 25 mph 0.19 CFM/FT
Thermal-NFRC 100-97
  U-Value U-Value
Size 36" x 60" 48" x 72"
Clear .46 .47
Low-E/Argon (ClimaTech) .31 .30
Low-E/Argon SST .29 .29

Top of Page


Select below for more information:
Home | About Us | Contact Us | Comparisons | Installation | Q & A | Resource Links | Instructions | Worksheet | Measuring | Instant Pricing | Products | Warranties | References | Vinyl Siding Denver Colorado